BS ISO 22955:2021 for Office Fit-Outs: What It Covers

4 min read
November 19, 2026
Open-plan office with white ceiling rafts holding ring lights, blue carpet and desk planters
Written by
Enis Murat Çakır, Acoustic Consultant at Acoustic Design & Architecture
Enis Murat Çakır
Acoustic Consultant
Get new insights
We respect your privacy and never share your information.
You're now part of our acoustic design community.
Something didn't work. Please try again.
Spread the word

Most acoustic complaints in open-plan offices come down to the same mismatch: the room was designed for one kind of work, and the people in it are doing several kinds at once. ISO's own introduction names the tension plainly: spoken communication and focused individual work pull in opposite directions. BS ISO 22955:2021, titled Acoustic quality of open office spaces, was written for that problem.

It is aimed at the people planning, designing and fitting out offices, and it is meant to give them a shared basis for writing an acoustic specification.

Six space types, not one target

The standard starts by asking what happens in the space. The contents page in the published preview of ISO 22955 lists six types:

  1. Space type 1: activity not known yet, such as a vacant floor plate.
  2. Space type 2: activity mainly focused on communication outside the room, by telephone, audio or video.
  3. Space type 3: activity based mainly on collaboration between people at nearby workstations.
  4. Space type 4: activity with a small amount of collaborative work.
  5. Space type 5: activity that can involve receiving the public.
  6. Space type 6: several activities combined in the same space.

For each one it describes the noise environment and the acoustic challenge, then gives indicators and values. Space type 1 matters for developers and landlords: a floor can be assessed before anyone knows who will move in.

Many activity-based floors end up as space type 6, and it is often the hardest one to get right.

The numbers it uses

The standard builds on the descriptors used for open-plan measurement in ISO 3382-3:

  • D2,S: how quickly speech level falls, in dB, each time the distance from the talker doubles.
  • Lp,A,S,4m: how loud speech is at 4 m from the talker.

It then adds a new one, DA,S, the in situ acoustic attenuation of speech. It compares speech at 1 m from the source with the level at a chosen receiving point, so it answers a practical question: how much quieter is a voice by the time it reaches this desk?

For space type 6, a 2025 paper from Müller-BBM reports the range the standard recommends. The paper gives the lowest value as 12 dB, between two acoustically active areas such as an informal meeting zone and a circulation route. It gives the highest as 32 dB, between a highly active social space and an area of focused individual work.

Those are the only values we quote here, because the full tables sit in the paid standard, which we have not reproduced. Get a copy, or have your acoustician work from it, before you write target values into a specification.

What this usually means on site

The ceiling is usually the first move. It is the largest untreated surface in most offices and the first place reflected sound builds up, so absorptive ceiling treatment tends to be the primary control. How much you need depends on the floor, so it is worked out for each project.

Absorption alone won't reach the higher DA,S values, though. The Müller-BBM analysis found that 26 and 32 dB often need more distance than a typical office has, and that those values can only be met with effective shielding. That changes the conversation at layout stage:

  • Zoning: keep kitchenettes, informal meeting areas and circulation away from focused work.
  • Shielding: use screens or partitions between zones that need a large difference.
  • Enclosed rooms: give calls and confidential talks somewhere to go, such as a meeting room or an acoustic pod.

Wall panels play a supporting role, useful near noise sources or glazed partitions. Acoustic furniture helps at the local level. Sound masking has its own informative annex in the standard, and the standard also covers workstation spacing, screens and accessibility.

Using it in a fit-out brief

  1. Map the floor by activity, then give each zone a space type.
  2. Agree which zones must be protected from which.
  3. Write the indicators and values from the standard into the brief.
  4. Model the layout before the furniture plan is fixed, as zoning and shielding are cheap to change on paper.
  5. Measure on completion if the brief requires it.

The standard also includes an example user survey and a section on open-plan etiquette. Both are useful, because acoustics alone won't settle how a team uses its space.

Where it gets written into a brief

BS ISO 22955:2021 can be used alongside other office acoustic references. Where a landlord or client writes it into a specification, it becomes a project requirement, so check the lease and the employer's requirements early.

Common questions

Is BS ISO 22955:2021 a legal requirement? No. It's a standard rather than statutory law. It applies to your project when a landlord, client or design team makes it part of the brief.

How much of the ceiling needs treating? There is no single figure. It depends on ceiling height, existing hard surfaces, zoning and the values in your brief, which is why a survey matters more than a rule of thumb.

Does reverberation time still matter? It is part of the picture, but on an open floor the descriptors above tell you more, as they track how speech travels across the room.

Can a small office ignore the space types? The principles still apply at any scale, though a smaller floor with fewer zones needs a lighter specification than a large, mixed-activity floor plate.

Getting your office specified against it

See our guide to fixing open-plan office acoustics or book a free survey to find out what your specific floor needs.

Related product guides: acoustic ceilings: tiles, baffles or rafts, acoustic pods.

From first survey to final finish

Seven stages, one point of contact. Book a free survey or call +44 1908 880191, and we'll come back to you with the next step.

Ruler icon
Acoustic Survey

An acoustician visits the site, or works from your drawings and photos when a visit isn't practical. Either way, the room, its surfaces and how it is used are recorded before any advice is given.

Summary icon
Acoustic Assessment

Reverberation, ambient noise and noise transfer are read against what the space is used for. The findings arrive as an AI-assisted acoustic report with recommendations, yours to keep with no obligation to proceed.

Design services icon
Acoustic Design

Treatment is modelled against a reverberation target, then drawn up with panel positions, fixings and finishes. Nothing moves forward until you have approved the design.

Request a quote icon
Specification & Quotation

Every quotation comes with the specification behind it, listing products by type, quantity and finish with costs set out line by line. What is quoted is what the design calls for.

Delivery truck icon
Acoustic Product Supply

Panels, baffles, ceilings and screens come from the manufacturers we work with and are supplied to the approved specification. What arrives on site matches what was designed.

Engineering icon
Acoustic Installation

Our installation team fits to the approved drawings, checking positions and fixings as they go. One team supplies and installs the treatment.

Fact check icon
Acoustic Testing & Compliance

Optional paid add-on: after fit-out the space can be measured again and compared with the original survey, so the improvement is measured rather than assumed. Compliance testing is carried out with our testing partner, EMC Acoustics, and the written record goes into your building file.

Stay connected with insights

Get the latest updates from our acousticians

By subscribing, you agree to receive our latest news and professional updates.
Thanks for subscribing to our insights
Something went wrong. Please try subscribing again.