A small meeting room with glass walls looks modern right up until someone needs a private conversation in it. Hard surfaces make the room echo, and the same glass that lets light in does little to stop speech leaking out into the corridor. Anything confidential ends up half-audible to whoever's walking past at the wrong moment.
Those are two separate faults with two separate measurements. Fixing one does not fix the other, so it pays to work out which one you have before you buy anything.
Echo and privacy are different problems
Echo is about what happens to sound inside the room. Speech bounces between glass, plasterboard, table and ceiling, so words overlap and people raise their voices. Absorption fixes this.
Privacy is about what reaches the person outside. That depends on the sound insulation of the partition, the door and the ceiling line, and on how loud the background is on the far side. Absorption helps a little, because a calmer room means quieter talkers, but it can't turn a weak partition into a strong one.
What glass does to speech
Glass is hard and flat, so it reflects speech back into the room almost completely. Two glass walls facing each other can also set up a fast repeating flutter that a video call picks up clearly.
On the privacy side, the pane itself is rarely the whole story. Sound takes the easiest route, and in a glazed meeting room that is often not the glass at all. Check these points first:
- The door: a glass door without seals leaves a gap around its edge, and speech goes straight through it.
- The ceiling line: a partition that stops at the suspended ceiling lets sound travel over the top through the void.
- Mullions and junctions: gaps where the partition meets the façade, the floor or the next wall all leak.
- Services: shared ductwork can carry speech from room to room.
An expensive partition with an unsealed door performs like the door. So look at the weakest element first.
The numbers to aim for
There is no single UK figure for an office meeting room, so these are the references worth using.
- Background noise: an acoustic report filed with a Camden office planning application, quoting BS 8233:2014, gives a design range of 35 to 45 dB LAeq for meeting rooms. In schools, BB93 sets an upper limit of 40 dB for a new-build meeting room and 45 dB for a refurbishment. Above that range, a call or a quiet voice starts to struggle.
- Reverberation time: about 0.6 seconds is a practical starting target for a small speech room. Our RT60 guide works through that sum for a room of 240 m³. An untreated room of that size can sit close to 3 seconds.
- Partition performance: the same Camden report sets 48 dB Rw for meeting rooms and cellular offices. Treat that as an indication, not a rule. Rw is a laboratory figure, and the same partition performs lower on site once doors, junctions and flanking paths are included.
How each one is measured
Echo: reverberation time is measured to BS EN ISO 3382-2, usually octave by octave across the speech range. Ask for the mid-frequency figure and the octave values.
Privacy: on-site sound insulation between rooms is reported as DnT,w, which measures the finished partition, not the product in a laboratory. Background noise is measured separately as LAeq, because the same partition gives more privacy beside a noisy corridor than beside a silent one.
Speech clarity: the Speech Transmission Index (STI) rates how intelligible speech is on a scale of 0 to 1. Inside the room you want it high. Outside the room you want it low. DataKustik's CadnaR documentation, which follows ISO 3382-3, puts privacy distance in open-plan offices at the point where STI falls below 0.20, and that is a useful way to think about privacy.
Working with glass, not against it
Glazed meeting rooms are common because they look good and keep sightlines open, and removing the glass usually isn't an acceptable trade-off. Wall panels on the solid walls and ceiling absorption overhead do the work the glass can't. Start with the ceiling, as it is usually the largest free surface, then treat the wall facing the glazing. Felt pendants over the table can add a little more without taking wall space. See acoustic lighting for what they can and can't do.
Adding sound masking where echo control isn't enough
For rooms where speech privacy is the main concern, we can add sound masking alongside wall and ceiling absorption. Absorption controls the room's internal acoustics, and masking raises the ambient level just enough outside the room that conversation carrying past the glass becomes harder to follow.
Treatment that takes no floor space
Most single meeting rooms are treated with wall and ceiling panels that take up no floor space and don't affect how the room is laid out or used. Where a room can't be made private enough, an acoustic pod on the open floor is often the simpler route for confidential calls.
Common questions
Will this stop conversations being overheard outside? Absorption reduces how much sound builds up in the room, but glass and door gaps still let speech through. For stronger speech privacy, look at the door seals and the partition head, and consider sound masking.
Can you treat a room with glass walls? Yes. Treatment goes on the solid surfaces and the ceiling, so the glazing stays as it is.
Can you work to the WELL Building Standard? Where it's relevant to your office, we can specify against the WELL Sound concept.
Solving your privacy problem properly
See our guide to open-plan office acoustics, our meeting room acoustics page, or book a free survey to find out whether your room needs absorption, better sealing, masking, or a mix.
Related product guides: acoustic pods, acoustic wall panels.
From first survey to final finish
Seven stages, one point of contact. Book a free survey or call +44 1908 880191, and we'll come back to you with the next step.
An acoustician visits the site, or works from your drawings and photos when a visit isn't practical. Either way, the room, its surfaces and how it is used are recorded before any advice is given.
Reverberation, ambient noise and noise transfer are read against what the space is used for. The findings arrive as an AI-assisted acoustic report with recommendations, yours to keep with no obligation to proceed.
Treatment is modelled against a reverberation target, then drawn up with panel positions, fixings and finishes. Nothing moves forward until you have approved the design.
Every quotation comes with the specification behind it, listing products by type, quantity and finish with costs set out line by line. What is quoted is what the design calls for.
Panels, baffles, ceilings and screens come from the manufacturers we work with and are supplied to the approved specification. What arrives on site matches what was designed.
Our installation team fits to the approved drawings, checking positions and fixings as they go. One team supplies and installs the treatment.
Optional paid add-on: after fit-out the space can be measured again and compared with the original survey, so the improvement is measured rather than assumed. Compliance testing is carried out with our testing partner, EMC Acoustics, and the written record goes into your building file.
Stay connected with insights
Get the latest updates from our acousticians