Acoustic Panel Fire Ratings Explained: Euroclass and Class 0

If you last specified acoustic panels before 2025, the fire rating rules have moved, and it's worth checking your assumptions before you spec the next project. Class 0, the old British benchmark most people still reach for by habit, no longer satisfies building control on its own for new work.
What changed, and when
Class 0 came from BS 476 Parts 6 and 7, a British testing system that measured surface flame spread but never assessed a product's core combustibility, smoke production, or flaming droplet behaviour. Following the Grenfell Tower inquiry, the national classification system was removed from Approved Document B, and from 2 March 2025 a Class 0 rating alone no longer satisfies building control for new construction. Projects now need to specify against the European Euroclass system, BS EN 13501-1, instead.
Reading a Euroclass rating
A Euroclass rating has two parts. The letter, A1 through F, rates reaction to fire, how much a material contributes to fire growth. The suffixes that follow rate smoke production (s1 being the best, lowest smoke, through to s3) and flaming droplets (d0 meaning none, through to d2). A rating of B-s1,d0 means: strong resistance to contributing to fire spread, minimal smoke generation, and no flaming droplets, materially more information than Class 0 ever provided, since Class 0 had no smoke or droplet measurement at all.
What rating your project actually needs
Requirements vary by room type and building use under Approved Document B. Many offices and meeting rooms are required to achieve at least C-s3,d2 as a regulatory minimum, but a growing number of commercial projects specify B-s1,d0 as their working baseline, comfortably above the minimum and a safer position for anything used by the public or vulnerable occupants, schools, healthcare, hospitality. For genuinely high-risk applications, escape routes, high-occupancy assembly spaces, the requirement can go higher still, and should be confirmed with your building control body or fire engineer rather than assumed.
Why this isn't just a compliance checkbox
Fire performance and acoustic performance aren't automatically in tension, but they can pull against each other in material selection. Some of the most acoustically efficient low-cost foams have historically had weaker fire performance, which is part of why mineral wool, naturally fire-resistant without additional treatment, has become the default core material for many commercial-grade acoustic panels. A product's NRC figure means nothing if it can't clear the fire rating your building actually requires.
Common questions
Can I still use products rated only to Class 0? For new work, Class 0 alone is no longer sufficient for building control sign-off as of March 2025; specify against the Euroclass system instead, and check with your supplier whether their products carry current Euroclass certification.
Does every room in a building need the same fire rating? No, requirements vary by use and risk, escape routes and high-occupancy spaces typically carry stricter requirements than a standard office or meeting room.
Specifying the right product for your building
See our acoustic solutions for fire-rated product options, or book a free survey to confirm exactly what your project needs before you order.
Related product guides: acoustic wall panels, industrial acoustic panels.
From first survey to final finish
One team handles all seven stages, the same way on every project, so you always know what happens next.
A surveyor visits the site, or works from your drawings and photos when a visit isn't practical. Either way, the room, its surfaces and how it is used are recorded before any advice is given.
Reverberation, ambient noise and noise transfer are read against what the space is used for. The findings arrive as a written report with recommendations, yours to keep with no obligation to proceed.
Treatment is modelled against a reverberation target, then drawn up with panel positions, fixings and finishes. Nothing moves forward until you have approved the design.
Every quotation comes with the specification behind it, listing products by type, quantity and finish with costs set out line by line. What is quoted is what the design calls for.
Panels, baffles, ceilings and screens come from our Acoustic Solutions range and are supplied to the approved specification. What arrives on site matches what was designed.
Our own engineers fit to the approved drawings, checking positions and fixings as they go. One team supplies and installs, so nothing is handed between contractors.
Optional: after fit-out the space can be measured again and compared with the original survey, so the improvement is measured rather than assumed. Results are reported against the relevant standards and the written record goes into your building file.
Stay connected with insights
Get the latest updates from our acoustic design experts